Konica minolta error code c0510

konica minolta error code c0510

Solution To clear the fuser error code, perform the following after correcting the cause: 1. With power ON, open the front door and locate the small. Second hand used Machine C350 displays C-0510 error code at startup. Trouble reset does not appear bu pressing Utility counter button during. Konica Minolta Copiers Error Code Messages. Some error codes do not C0510 Low fuser temperature. C0520 High fuser temperature. C0602 Scan cable problem.

Very: Konica minolta error code c0510

RUNTIME ERROR LORD OF RINGS
Error e22 en canon mp140
Lineage gameguard error 114
Konica minolta error code c0510
konica minolta error code c0510

Konica minolta error code c0510 - words... super

favorite_border fotocopidora konica minolta bizhub 210 error co500

bueno llevas buscando el manual pues premio te lo mando si no te llega dame una pagina ftp de momento te mando lo preciso

hola amigos.
estoy revizando una maquina konica bizhub 210,la falla que presenta inmediatamente se enciende,muestra, averia de maquina CO500 y luego se apaga y la dificultad que tengo es que no cuento con manual de servicio,les agradesco de antemano su colaboraciòn.[/quote:1691b7f5e9]Field Service Ver. 1.0 Apr. 2005 15. Malfunction code
141
bizhub 162
bizhub 210
Troubleshooting
15.3.7 C0500: Warm-up Failure
15.3.8 C0501: Warm-up Failure 2 (bizhub 210 Only)
15.3.9 C0510: Fusing Failure (Abnormally Low Fusing Temperature)
15.3.10 C0511: Fusing Failure (Abnormally Low Fusing Temperature 2)
(bizhub 210 Only)
15.3.11 C0520: Fusing Failure (Abnormally High Fusing Temperature)
15.3.12 C0521: Fusing Failure (Abnormally High Fusing Temperature 2)
(bizhub 210 Only)
A. Detection Timing
Trouble Code Description
C0500
• The surface temperature of the Fusing Roller does not reach a given level even
after the lapse of a given period of time during a warm-up cycle.
From room temperature to 100°C : 35 sec.
From 100°C to 140°C : 25 sec.
From 140°C to the completion of the warm-up cycle : 20 sec.
C0500
• The Fusing Roller Thermistor does not detect a predetermined temperature
within 30 sec. after a warm-up cycle has been started and thus the warm-up
cycle is not completed.
• The surface temperature of the Fusing Roller does not reach a given level even
after the lapse of a given period of time during a warm-up cycle.
From room temperature to 60°C : 4 sec.
From 60°C to 100°C : 2 sec.
From 100°C to 130°C : 1 sec.
From 130°C to 155°C : 0.5 sec.
C0501
• The Fusing Roller Sub Thermistor does not detect a predetermined temperature
within 30 sec. after a warm-up cycle has been started and thus the warmup
cycle is not completed.
• The surface temperature of the Fusing Roller does not reach a given level even
after the lapse of a given period of time during a warm-up cycle.
From room temperature to 60°C : 7 sec.
From 60°C to 100°C : 2 sec.
From 100°C to 130°C : 1 sec.
From 130°C to 155°C : 0.5 sec.
C0510
• The surface temperature of the Fusing Roller remains lower than 120°C (105°C
for the model having two Fusing Roller Heater Lamps) for a given period of time
during the standby state.
• The surface temperature of the Fusing Roller remains lower than 120°C (105°C
for the model having two Fusing Roller Heater Lamps) for a given period of time
during a print cycle.
C0511
• The temperature detected by the Fusing Roller Sub Thermistor remains lower
than 105°C for a given period of time during the standby state.
• The temperature detected by the Fusing Roller Sub Thermistor remains lower
than 105°C for a given period of time during a print cycle.
C0520
• The temperature detected by the Fusing Roller Thermistor remains higher than
240°C for a given period of time.
C0521
• The temperature detected by the Fusing Roller Sub Thermistor remains higher
than 240°C for a given period of time.
15. Malfunction code Field Service Ver. 1.0 Apr. 2005
142
bizhub 162
bizhub 210
Troubleshooting
B. Detection Timing
Relevant Electrical Components
Fusing Roller Heater Lamp (H1)
Fusing Roller Sub Heater Lamp (H2)
Fusing Roller Thermistor
Fusing Roller Sub Thermistor (TH2)
Fusing Roller Thermostat (TS1)
Fusing Unit Interlock Switch (S2)
Power Supply Unit (PU1)
Master Board (PWB-A)
Step Operations
Ref.
Page
WIRING DIAGRAM
Control signal
Location
(Electrical
Components)
1
Check that the Fusing Roller Heater
Lamp (H1) turns ON when the Power
Switch is turned ON and correct or
replace the lamp as necessary.
– – –
2
Check that the Fusing Roller Sub
Heater Lamp (H2) turns ON when
the Power Switch is turned ON and
correct or replace the lamp as necessary.
– – –
3
Check the Fusing Roller Thermostat
(TS1) for operation.
<Check procedure>
Check the resistance of TS1. TS1 is
open-circuited if its resistance is
infinity.
– – F-2
4
Check the Fusing Unit Interlock
Switch (S2) for operation.
<Check procedure>
Check continuity across the following
terminals when S2 is ON.
• Across S2-1A and S2-1B
• Across S2-2A and S2-2B
– – E-16
5
Check the Fusing Roller Thermistor
(TH1) and Fusing Roller Sub Thermistor
(TH2) for installation and correct
or clean as necessary.
– – –
6
Check the Fusing Roller Thermistor
(TH1) for operation.
<Check procedure>
Disconnect CN15 (4P) and check the
resistance across CN15-2 and 3 on
the Thermistor side. TH1 is open-circuited
if the resistance is infinity.
– – D-2
7
Check the Fusing Roller Sub Thermistor
(TH2) for operation.
<Check procedure>
Disconnect CN22 (4P) and check the
resistance across CN22-2 and 3 on
the Thermistor side. TH2 is open-circuited
if the resistance is infinity.
– – D-2
Field Service Ver. 1.0 Apr. 2005 15. Malfunction code
143
bizhub 162
bizhub 210
Troubleshooting
8
Check the Fusing Roller Heater
Lamp (H1) for continuity and correct
or replace as necessary.
– – –
9
Check the Fusing Roller Sub Heater
Lamp (H2) for continuity and correct
or replace as necessary.
– – –
10 Change PU1. – – –
11 Change PWB-A. – –

15. Malfunction code Field Service Ver. 1.0 Apr. 2005
134
bizhub 162
bizhub 210
Troubleshooting
15.2 How to reset
Code Description Procedure
C0000 Main Motor malfunction
• Turn OFF and ON the Power Switch.
C0044 ADF Cooling Fan Failure
C0045 Fusing Cooling Fan Motor malfunction
C004E
Power Supply Cooling Fan Motor malfunction
C0070 Toner Replenishing Motor malfunction
C0210 Abnormal image transfer voltage
C03FF Faulty Model Setting
• Make the correct setting for “Model Setting”
of “Adjust” available from the Service mode.
☞ 97
C0500 Warm-up failure
• Turn ON the Power Switch with the Stop key
held down.
C0501 Warm-up failure 2
C0510
Fusing failure
(abnormally low fusing temperature)
C0511
Fusing failure
(abnormally low fusing temperature 2)
C0520
Fusing failure
(abnormally high fusing temperature)
C0521
Fusing failure
(abnormally high fusing temperature 2)
C0650 Faulty Scanner Home Position Sensor
• Turn OFF and ON the Power Switch.
C0B60 Bin Switching Motor malfunction
C0B80 Shift Motor malfunction
C0F32 Faulty ATDC Sensor
C0F33 Improperly adjusted ATDC Sensor
C1038 Engine connection failure
C1200 Faulty ASIC/memory
C1300 Polygon Motor malfunction
C133B Communication with option error
C133D ROM check error
C13F0 Faulty HSYNC
C1468 Faulty Parameter Chip
C14A3 IR fluorescent lamp fault

amigo apaga la maquina ten presionado el boton de stop y asunto solucionado...asi de simple ok.... eso es para todas las bizhub de menos de 21 copias suerte

al estar apagada la maquina y tener presionado el boton de stop lo prendes ok con el boton stop presionado

Muy buenos días para todos ... Pueden envíame el manual de este modelo vía correo : [email protected] ... Agradecido

¿Conoces la Solución? Enviar Solucionsend





[SOLVED] Quick fix Konica-Minolta 161f list error codes

[SOLVED] Quick fix Konica-Minolta 161f list error codes

– Compatible Printer model: Konica-Minolta bizhub 161f
– Konica-Minolta bizhub 161f Error Codes with quick guides:

  • Code: C0045
  • Description: Fuser fan motor error
    – The LOCK signal remains HIGH or LOW continuously for a predetermined period of time while the Cooling Fan Motor remains energized
  • Troubleshooting Guides: 1 Check the Motor connectors for connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M2 operation check 4 M3 operation check 5 Replace PWB-P.
  • Code: C0210
  • Description: H. V. abnormal
    – The Drum Charge Monitor Voltage (HVC_MON) signal falls outside a predetermined range at any time after the lapse of a predetermined period of time after the Power Switch has been turned ON.
    – The Image Transfer Voltage Monitor signal (T_MON_V) and Image Transfer Current Monitor signal (T_MON_I) fall outside a corresponding predetermined range
  • Troubleshooting Guides: 1 Replace Fusing Unit. 2 Replace PWB-P.
  • Code: C0500
  • Description: Fuser warm up error
    – The voltage of the Thermistor remains low for a predetermined period of time when a warm-up cycle is started.
    – The temperature detected by the Thermistor remains lower than a reference value for a predetermined period of time for the period of time that begins 5 sec. after, and ends 9 sec. after, the start of the warm-up cycle (where the temperature detected by the Thermistor is 80 °C or less).
    – The temperature detected by the Thermistor does not increase for a 3-sec. period or more for the period of time that begins after the lapse of a predetermined period of time after the Fusing Roller Heater Lamp has been turned ON and ends when the lamp is turned OFF.
    – The Fusing Roller Heater Lamp remains ON for a 30-sec. period or more (except during the period through which the Main Motor remains energized).
  • Troubleshooting Guides: 1 Replace Thermistor (TH1). 2 Replace Fusing Unit. 3 Replace Controller/Mechanical Control Board (PWB-P). 4 Replace Power Unit (PU1).
  • Code: C0510
  • Description: Fuser temperature low
    – The temperature detected by the Thermistor remains lower than the set temperature continuously for a predetermined period of time while the fusing temperature control is being provided. (The set temperatures are as follows: 140 °C during a print mode at 600 dpi; 70 °C during the standby mode.)
  • Troubleshooting Guides: 1 Replace Thermistor (TH1). 2 Replace Fusing Unit. 3 Replace Controller/Mechanical Control Board (PWB-P). 4 Replace Power Unit (PU1).
  • Code: C0520
  • Description: Fuser overheat
    – The temperature detected by the Thermistor remains higher than 235 °C for a predetermined period of time while the fusing temperature control is being provided.
  • Troubleshooting Guides: 1 Replace Thermistor (TH1). 2 Replace Fusing Unit. 3 Replace Controller/Mechanical Control Board (PWB-P). 4 Replace Power Unit (PU1).
  • Code: C0650
  • Description: Scanner home sensor error
    – The Scanner Home Position Sensor is not detected within the predetermined period of time after the Scanner Motor has started turning.
  • Troubleshooting Guides: 1 M4 operation check. 2 Replace PWB-P.
  • Code: C1200
  • Description: ASIC memory abnormal
    – An error occurred while writing to or reading the SRAM on the Control Board (PWB-C).
  • Troubleshooting Guides: 1 Turn the copier off, then on again. 2 Check the connection of the memory on the PWB-P, and then correct it if necessary. 3 Replace PWB-P.r unit.
  • Code: C1300
  • Description: Polygon mirror motor error
    – The LOCK signal is not detected within a predetermined period of time that begins 1 sec. after the Polygon Motor has been energized.
    – No new LOCK signal is detected for a 1-sec. period that begins 1.5 sec. after the first LOCK signal was detected.
    – The LOCK signal is not detected for a continuous 0.5-sec. period in a state in which the Polygon Motor runs stably.
    – The LOCK signal remains ON for a continuous 5-sec. period or more when the Polygon Motor remains deenergized.
  • Troubleshooting Guides: 1 Check cables for connection and correct as necessary. 2 Replace PH Unit. 3 Replace PWB-P.
  • Code: C133B
  • Description: Communication with option error
    – Communication could not be established with the Controller Control Board within 5 seconds while printing.
  • Troubleshooting Guides:
  • Code: C133C
  • Description: Modem error
    – A malfunction occurred in the Modem.
  • Troubleshooting Guides: 1 Replace NCU.
  • Code: C133D
  • Description: ROM checksum error
    – A malfunction occurred in the ROM
  • Troubleshooting Guides: 1 Replace PWB-P.
  • Code: C13F0
  • Description: Laser error
    – The laser output exceeds the upper limit value.
    – The laser output remains lower than the lower limit value.
  • Troubleshooting Guides: 1 Check cables for connection and correct as necessary. 2 Replace PH Unit. 3 Replace PWB-P.
  • Code: C1468
  • Description: Parameter Chip error
    – An Parameter Chip not written with initial data was detected.
  • Troubleshooting Guides: 1 Unplug, then plug in the power cord, and turn off the copier, then turn it on again. 2 Check the connection of the Parameter Chip on the PWBP, and then correct it if necessary. 3 Replace PWBP. 4 Replace Parameter Chip.
  • Code: C14A3
  • Description: IR lamp malfunction
    – The luminosity level of the Exposure Lamp is not stabilized within the predetermined period of time.
  • Troubleshooting Guides: 1 Check the connection of the connectors, and then correct them if necessary. 2 Replace PWB-P. 3 Replace the Scanner Assy.


Quick fix Konica-Minolta 161f list error codes

Solve Konica-Minolta bizhub 161f Error codes







– Get more error code list with quick guide to fix printer product, click here
– About get help with reseting Epson inkpad or others, click here






– Get more information about Epson XP 15000 troubleshooting, click here
– Buy cheap key of Epson WIC Reset Tool, CLICK HERE
– Key Epson Adjustment Program, CLICK HERE
– Download Epson printer driver, CLICK HERE
– Download Epson XP-6100 Driver, Firmware and Manuals, CLICK HERE

Contact us to get support with Konica-Minolta bizhub 161f Error case

Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.

Filed Under: error code, Konica-MinoltaTagged With: fix Konica-Minolta 161f, Konica-Minolta 161f repair service, Konica-Minolta 161f troubleshooting, Konica-Minolta bizhub 161f Error

Konica-Minolta bizhub C350

  • Catalog

  • Sign In

  • Contacts

  • Forum

  • Eng

    • Code: C0510
    • Description: Heating Roller abnormally low temperature
      • No zero cross signal is detected even with the lapse of 1 sec. or more during a standby state, print cycle, or Power Save. • A temperature of 120 °C or less of the Heating Roller is detected for 1 sec. or more during a standby state. • A temperature of 120 °C or less of the Heating Roller is detected for 1 sec. or more during a print cycle. • A temperature of 70 °C or less of the Heating Roller is detected for 1 sec. or more during Power Save.
    • Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PWB-MC and PU1 for proper connection and correct or change as necessary. 3 Change Fusing Unit. 4 Change PWB-MC. 5 Change PU1.

    PrintCopy .info service 2001 - 2022

    Error Code
    Parts Catalog
    Service Mode, Troubleshooting
    Compatibility
    Home

    Konica-Minolta bizhub 162

    • Catalog

    • Sign In

    • Contacts

    • Forum

    • Eng

      • Code: C0510
      • Description: Fusing failure (abnormally low fusing temperature)
        - The temperature detected by the Fusing Roller Thermistor remains lower than 120°C (105°C for the model having two Fusing Roller Heater Lamps) for a given period of time during the standby state.
        - The temperature detected by the Fusing Roller Thermistor remains lower than 120°C (105°C for the model having two Fusing Roller Heater Lamps) for a given period of time during a print cycle.
      • Remedy: 1 Check that the Fusing Roller Heater Lamp (H1) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 2 Check that the Fusing Roller Sub Heater Lamp (H2) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 3 Check the Fusing Roller Thermostat (TS1) for operation. <Check procedure> Check the resistance of TS1. TS1 is open-circuited if its resistance is infinity. 4 Check the Fusing Unit Interlock Switch (S2) for operation. <Check procedure> Check continuity across the following terminals when S2 is ON. • Across S2-1A and S2-1B • Across S2-2A and S2-2B 5 Check the Fusing Roller Thermistor (TH1) and Fusing Roller Sub Thermistor (TH2) for installation and correct or clean as necessary. 6 Check the Fusing Roller Thermistor (TH1) for operation. <Check procedure> Disconnect CN15 (4P) and check the resistance across CN15-2 and 3 on the Thermistor side. TH1 is open-circuited if the resistance is infinity. 7 Check the Fusing Roller Sub Thermistor (TH2) for operation. <Check procedure> Disconnect CN22 (4P) and check the resistance across CN22-2 and 3 on the Thermistor side. TH2 is open-circuited if the resistance is infinity. 8 Check the Fusing Roller Heater Lamp (H1) for continuity and correct or replace as necessary. 9 Check the Fusing Roller Sub Heater Lamp (H2) for continuity and correct or replace as necessary. 10 Change PU1. 11 Change PWB-A.

      PrintCopy .info service 2001 - 2022

      Error Code
      Parts Catalog
      Service Mode, Troubleshooting
      Compatibility
      Home
      Copytechnet.com

      Thanks Thanks:  0
      Likes Likes:  0
      Dislikes Dislikes:  0
      1. Technician
        Join Date
        Sep 2009
        Location
        ca
        Posts
        16
        Rep Power
        27

        Unhappy C0510 Error code on Minolta Di550

        Hi,

        I have a Konica Minolta Di550, and today it stopped working causing an error saying C0510, How to fix it? i've checked out the orange fuser ( i don't know its name in english ) and i found it colder than what it's expected to be.

        Nowadays the weather is cold here in my region. Any ideas of how to bypass this error?

        Thanks


      2. Technician
        Join Date
        Sep 2009
        Location
        ca
        Posts
        16
        Rep Power
        27
        Thank you so much! i've fixed it by adding a lamp to the one that is already exists ( there was only one ). and now it's working!!!


      3. Technician
        Join Date
        Sep 2009
        Location
        ca
        Posts
        16
        Rep Power
        27
        Hi Brent,
        Yes, there was only one lamp because my region is so hot in summer and now it's cold and that what caused the error which means a very low temprature.

        Thank you very much for taking the time to get more explantion!!


      Quick NavigationKonica MinoltaTop
      • Site Areas
      • Settings
      • Private Messages
      • Subscriptions
      • Who's Online
      • Search Forums
      • Forums Home
      • Forums
      • System Forums
        1. System Announcements
        2. Site Feedback & Questions
        3. Newbie Check In!
      • Technical Forums
        1. Copier Technical Discussion
          1. Canon
          2. Konica Minolta
          3. Kyocera Mita, Copystar
          4. Muratec
          5. Panasonic
          6. Ricoh, Savin, Gestetner, Lanier
          7. Sharp
          8. Samsung
          9. Toshiba
          10. Xerox
          11. Other Copier Brands
        2. Fax & Printer Technical Discussion
          1. Brother
          2. Canon
          3. HP
          4. Kyocera
          5. Lexmark
          6. Ricoh
          7. Other Brands
        3. Digital Duplicators
        4. Connectivity
        5. Cash Registers, Calculators, Telecom, Other...
        6. Service Manual Requests
        7. Business Talk
        8. For Sale, Trade, or Wanted
        9. The Parts Room
        10. Employment
      • Non-Technical Forums
        1. Rants, Raves, and Everything Else
        2. Gamers' Forum
        3. Industry News
        4. Test Forum

      Tags for this Thread

      bypass, code, error, found, fuser, fusing unit, konica, konica minolta, lef, minolta, region, stopped

      View Tag Cloud

      Posting Permissions

      • You may not post new threads
      • You may not post replies
      • You may not post attachments
      • You may not edit your posts
      •  

      Forum Rules

      Copytechnet.com

      Thanks Thanks:  0
      Likes Likes:  0
      Dislikes Dislikes:  0
      Quick NavigationKonica MinoltaTop
      • Site Areas
      • Settings
      • Private Messages
      • Subscriptions
      • Who's Online
      • Search Forums
      • Forums Home
      • Forums
      • System Forums
        1. System Announcements
        2. Site Feedback & Questions
        3. Newbie Check In!
      • Technical Forums
        1. Copier Technical Discussion
          1. Canon
          2. Konica Minolta
          3. Kyocera Mita, Copystar
          4. Muratec
          5. Panasonic
          6. Ricoh, Savin, Gestetner, Lanier
          7. Sharp
          8. Samsung
          9. Toshiba
          10. Xerox
          11. Other Copier Brands
        2. Fax & Printer Technical Discussion
          1. Brother
          2. Canon
          3. HP
          4. Kyocera
          5. Lexmark
          6. Ricoh
          7. Other Brands
        3. Digital Duplicators
        4. Connectivity
        5. Cash Registers, Calculators, Telecom, Other...
        6. Service Manual Requests
        7. Business Talk
        8. For Sale, Trade, or Wanted
        9. The Parts Room
        10. Employment
      • Non-Technical Forums
        1. Rants, Raves, and Everything Else
        2. Gamers' Forum
        3. Industry News
        4. Test Forum

      Posting Permissions

      • You may not post new threads
      • You may not post replies
      • You may not post attachments
      • You may not edit your posts
      •  

      Forum Rules

      Konica Minolta error codes

      Konica Minolta Copiers Error Code Messages


      Some error codes do not display, but can be read only in data collection, list output and KRDS.

      Click here to return

      C0000
      Main motor problem

      C0010
      M1 motor not running

      C0040
      Suction fan

      C0042
      Fuser fan

      C0044
      EDH fan

      C0045
      Fuser cooling fan motor problem, image reader fan

      C0046
      PH fan

      C0047
      PH fan

      C0049
      Vertical transport fan

      C004C
      Ozone fan motor

      C004E
      Power supply cooling fan problem

      C004F
      Power supply fan

      C0049
      Laser cooling fan problem

      C0070
      Toner bottle home sensor or toner motor problem

      C0072
      Toner hopper motor

      C0090
      Developer motor

      C0200
      High voltage problem

      C0210

      Transfer roller voltage problem 

      C0214
      Image transfer voltage problem 

      C03FF
      Adjust mode 11 done wrong 

      C0400
      Exposure lamp problem 

      C0420
      Exposure lamp problem 
      C0500Fuser problem, Warm-up incomplete 

      C0510
      Low fuser temperature 

      C0520
      High fuser temperature 

      C0602
      Scan cable problem 

      C0605
      Scan home problem 

      C0650
      Scan motor scan sensor problem 

      C0651
      Scan home problem 

      C0B00
      Finisher transport motor 

      C0B20
      Stapler unit drive motor problem 

      C0B0F
      Paper entry switch motor problem 

      C0B30CD
      Aligning motor 

      C0B38
      Shift motor 

      C0B48
      Exit roller motor problem, neat copy stack transport problem 

      C0B49, C0B4A, C0B4B, C0B4D, C0B4E, C0B4F
      Copy stack transport problem

      C0B4D
      Paper holding tray problem 

      C0B4E
      Finisher tray motor 

      C0B50
      Stapler motor 1 problem 

      C0B54
      Stapler motor 2 problem 

      C0B60
      Bin switching motor problem 

      C0B73, C0B74
      Punch motor problem 

      C0B78
      Hole position selector motor problem 

      C0B80
      Shift motor problem 

      C0BA0, C0BA1, C0BA2
      Elevator motor 

      C0BC0, C0BC1, C0BC2, C0BC3
      Paper folder problem 

      C0BF0
      Control system problem 

      C0D50
      Duplex horizontal motor problem 

      C0E00
      Erase lamp problem 

      C0F24
      AIDC sensor problem 

      C0F32
      ATDC sensor problem 

      C0F33
      ATDC sensor adjusted wrong 

      C0900
      3rd drawer lift problem 

      C09043rd drawer lift motor

      C0910
      2nd drawer lift problem 

      C0910
      2nd drawer lift motor 

      C0920
      1st drawer lift problem 

      C0924
      1st drawer lift motor 

      C0950
      4th drawer lift problem 

      C0954
      4th drawer lift motor  

      C0990
      LCC lift-up problem 

      C0991
      Lift 1 motor up problem 

      C0994
      Main tray elevator motor 

      C0995
      LCC transport motor problem 

      C0996
      Main tray lock release problem 

      C0997
      Shift gate problem 

      C0998
      Shift return problem 

      C0999
      Lift 2 motor up problem 

      C099C
      Shift motor problem 

      C09C0
      LCT elevator up/down problem 

      C099
      DCommunications problem 

      C10xx, C1xx, C1xx
      Memory board problem

      C1038
      Engine connection problem (PWB-A to PWB-C)  

      C1200
      System memory problem 

      C12CX
      Hard drive problem 

      C1300Polygon motor (Laser Motor) 

      C1326
      ARMS interface problem 
      C1330VD signal low 

      C133A
      Communication problem with gate array 

      C133B
      Communication problem with option I/F 

      C13C0
      Failure of imaging cartridge to initialize 

      C13D0
      Bad EEPROM 

      C13F0
      SOS sensor (Laser Problem), HYSYNC detect failure 

      C133B
      Communication problem with controller board 

      C1334
      Duplex problem 

      C13F1
      600 dpi sensor 

      C13F4
      Optics out of adjust range 

      C13F5
      LD1 intensity adjust problem 

      C13F6
      LD2 intensity adjust problem 

      C13F7
      Sub scan beam position adjust problem

      C13F8
      Main scan beam position adjust problem 

      C13F9
      EPROM error 

      C13FA
      LD2 out of range 

      C13FC
      APC problem 

      C1401
      IR main routine timeout 

      C1402
      IR illegal interrupt vector 

      C1410
      IR watchdog 

      C1426
      Report retransmitted 

      C1428
      Transmission buffer full 

      C1429
      Transmission hard error 

      E1430
      Gain problem 

      C1441
      CCD problem 

      C1450
      Sequence timeout 

      C1461
      Serial GA1 error 

      C1462
      Serial GA2 error 

      C143E
      EDH error 

      C14A3
      Exposure lamp problem 

      C1468
      EEPROM problem 

      C1470
      CCM to EVM communication error

      C1471
      EVM to SQM communication error 

      C1499
      Image reader fan problem  

      C14A3
      Exposure lamp problem 

      C18XX
      SCSI problem 

      E46-01, -02, -03, -05, -06, -08, -12
      Image control board 

      E46-13, -14, -15, -16, -17, -19, -21  

      E46-23, -24
      Image control board 

      E46-25
      A/D conversion board or exposure lamp 

      E46-27,-29, -30, -31, -32, -33, -34
      Image control board or image control program 

      E46-60
      Laser problem 

      E46-61
      Document feeder control board 

      E46-62
      Paper not centering 

      E46-63
      Exposure lamp 

      E46-64
      Toner control board 

      E46-80, -81,-82, -83
      Image control board 

      E46-90
      Image control board or DIMM contact 

      E46-91
      Image control board 

      E50-01, -02, -03, -04,-05
      Print control board 

      E50-10
      Printer control board or Image control board

      E50-11
      Image control board 

      E56-2
      Image control board  

      E60-01, -02, -03
      Image control board or Document feeder control board 

      E70-1, -2
      Finisher control board 

      E90-01, -02
      Duplex stand drive board   

      F10-1, -2, -9
      Communication error between printer board and copier 

      F13-01, -02
      Paper feed board or printer controller board 

      F13-03
      DC drive board 

      F18-1
      Upper paper feed lift problem 

      F18-2
      Lower paper feed lift problem 

      F18-3
      Upper DB lift problem 

      F18-10, -11, -12, -13, -20, -21, -22, -23
      Upper paper feed drive, DC drive board, printer control board or sensors 

      F18-30, -31, -32, -33
      Paper feed lift problem, DC drive board, Printer board 

      F18-40, -41, -42, -43
      LCT paper feed unit lift problem 

      F18-51, -52, -53
      Bypass up/down feed problem 

      F21-01, -02, -03
      Charge corona cleaning problem 

      F21-04, -05, -06
      Transfer or separation corona cleaning problem  

      F22-1
      Drum temperature too high

      F22-2
      PCL connector problem 

      F23-1
      PCL connector problem 

      F23-01
      Toner motor problem

      F23-02
      Developer motor 

      F23-03, -04, -05, -06, -07, -08, -09
      Cleaning blade problem 

      F23-10
      Drum problem (Drum motor or drive) 

      F23-11
      Toner supply drive problem 

      F24-01, -02, -04
      Drum temperature problem 

      F26-1, -2, -3
      Auto toner detect problem 

      F28-1
      Charge corona problem 

      F28-01
      High voltage unit 1 

      F28-2
      Transfer corona problem 

      F28-02, -03,-04
      High voltage unit 2 

      F28-3
      Separator corona problem 

      F28-4
      Developer problem at patch 

      F29-01, -02, -03, -04, -05, -06, -07, -08
      Toner control sensor board or print board 

      F29-12, -13, -14, -15
      High voltage unit 1 or 2 

      F32-01, -02, -03, -04, -05, -06, 07
      Fan motor problem, AC board or ADU stand drive board 

      F33-01
      Duplex registration area 

      F33-02
      Duplex paper reverse 

      F33-03
      Duplex transfer 

      F33-04
      Duplex exit

      F33-05
      Duplex web drive 

      F33-06
      Duplex web drive 

      F34-1
      High fuser temperature or bad thermistor 

      F34-2
      High fuser temperature 

      F35-1 THRU F-35-6
      Low fuser temperature or open thermistor 

      F35-7, -8
      Low fuser temperature or wrap jam 

      F35-9, -10
      Fuser thermistor  

      F36-1
      High fuser temperature at TH1 

      F36-2
      High fuser temperature at TH2 

      F36-3
      Open TH1 

      F36-4
      Open TH2 

      F37-1
      Replace fuser cleaning web 

      F40-1, -9
      Optics communication error 

      F41-1, -02, -03, -04, -05, -06, -07, -08, -09
      Scan return problem 

      F41-10, -11
      Laser polygon motor 

      F42-01, -02, -03
      Scan drive board or scan cooling fan 

      F42-04, -05, -06, -07
      DC drive board or laser cooling fans 

      F43-1
      Exposure lamp or lamp board problem  

      F46-1
      Laser motor problem 

      F46-8
      Laser index error 

      F46-10
      AOC error 

      F46-11
      AGC error 

      F49-2
      Laser board connector error 

      F49-4
      Index sensing board connection error 

      F49-6
      ADB (A/D conversion board) connection error 

      F51-4
      Developer speed problem 

      F51-5
      Main motor speed problem 

      F51-6
      Laser motor problem 

      F52-1
      Optics fan problem 

      F52-2
      Fuser fan problem 

      F52-01, -02
      AC drive board, fan 3 or fan 4 

      F52-3
      DC power supply fan 

      F52-03, -04
      AC drive board or fan3 

      F52-4
      Developer suction problem

      F52-05, -06
      AC drive board or fan 2 

      F52-6
      CPU fan problem 

      F52-07, -08, -09
      AC drive board or fan 3

      F52-10
      AC drive board fan 3 or fan 4 

      F52-11
      AC drive board or fan 6 

      F53-01
      Main motor 

      F53-02, -03
      AC drive board or total counter 

      F53-04, -05
      AC drive board or key counter 

      F53-06, -07, -08
      Printer board 

      F53-09
      Abnormal input voltage 

      F53-10, -11, -12
      Printer board, solenoids, motors 

      F56-1 THRU -11
      Communication problem, control board 

      F56-11, -12, -13
      O1, O2, O3 communication errors 

      F60-1
      RADF control board or main control board 

      F60-11R
      ADF control board 

      F67-3
      RADF control board or main control board 

      F70-1
      Communication problem between machine and finisher, main control board or finisher board 

      F70-9
      Finisher error caused by SRGA error detect 

      F70-11
      Finisher board 

      F77-2
      Finisher board, up/down motor or up/down detect sensor problem 

      F77-3
      Finisher alignment problem 

      F77-4
      Finisher up/down problem 

      F77-5
      Finisher board or pressure motor 

      F77-6
      Stapler problem or finisher board 

      F77-11
      Stapler motor 

      F77-16
      Finisher rear alignment error 

      F77-17
      Stapler motor or finisher board 

      F77-18
      Finisher fan problem 

      F77-22
      Rear alignment motor or sensor or finisher board 

      F80-1 THRU -5
      PRMB (Parameter Memory board) on control board 

      F80-10, -11, -12, -13
      C1, C2, C3 programs (Communication) 

      F80-21
      Video I/F programs 

      F80-31
      Printer cable or program file 

      F80-32
      Printer cable, program transfer destination board 

      F81-1, -2, -3
      Control board 

      F87-1, -2, -3
      Printer controller 

      F88-1
      Controller board 

      F89-1 THRU -6
      Controller board 

      F93-01
      Duplex stand drive board 

      F93-02
      Duplex conveyance  

      F93-03, -04
      Duplex reverse motor 

      F93-05, -06
      Duplex solenoids or motors 

      H1
      Memory capacity exceeded 

      H2
      Paper size mismatch 

      J1
      Internal jam 

      J2
      Internal jam 

      J06
      Bypass jam 

      J3
      Exit or fuser jam 

      J8
      Document feeder jam 

      J10
      Bypass jam 

      J11
      Upper feed jam 

      J12
      Upper feed jam 

      J13
      DB upper feed jam 

      J14
      DB lower feed jam 

      J16
      Jam in DB 

      J20-2
      Duplex door open 

      J20-3
      Finisher open 

      J20-4

      Emergency stop signal from copier  

      J20-5,-6
      Finisher open 

      J30
      Jam probably registration area 

      J31
      Exit jam

      J32
      Paper exit jam 

      J32-2
      Fuser exit jam 

      J33
      Paper exit jam  

      J50-1
      Print request failure 

      J50-2
      Valid signal failure 

      J50-3
      Registration did not start on time (Duplex) 

      J61-0,-1
      RADF open during run or other RADF jam 

      J62-0 THRU J62-5
      RADF feed problem 

      J63-0 THRU J63-5
      RADF internal or exit jam 

      J65-1, -2, -3
      RADF feed jam 

      J65-8
      RADF exit jam 

      J65-9, -10, -11
      RADF jams 

      J72-1, -2
      Finisher jam 

      J72-16
      Finisher entry jam 

      J72-17
      Finisher exit jam 

      J72-19
      Finisher entry jam 

      J72-21
      Finisher exit jam 

      J72-23
      Finisher exit jam 

      J72-81
      Stapler jam 

      J75-10, -11, -12, -13
      IT 101 jams 

      J81
      Duplex paper feed jam 

      J82
      DB or duplex feed jam 

      J90
      Fuser exit jam 

      J91
      Paper exit jam 

      J92
      Duplex jam 

      J-97-1, -2
      Duplex problem 

      J100
      Duplex jam 

      oA
      Document feeder misfeed guide open

      oL 
      Clamshell open 

      oU
      Document feeder open 