Unfortunately, the new LaserJet / series seems not to be absolutely compatible with older HP printers or it has a firmware bug. Sometimes it happens. Remedy: 1. Power cycle the printer by unplugging the printer and plugging it back in. 2. Make certain the Laser/Scanner Assembly is correctly seated on the. Liquid Chromatograph. Firmware Upgrade Procedures Updating Firmware of HP Series of HPLC modules error handling.

Hp 1100 firmware error - like

HP Business Inkjet and Printer Series - Firmware Error Codes

note:

The '??' field is for 'more error info.' Its contents are listed with each entry.

0x00 ( 0) is Ok. see pen_sprers.eu_result. Also for 2nd assert in Network debugging

0x01 ( 1) CB_32V_STUCK_ON (Fet in Main logic PCA is shorted)

0x02 ( 2) Black pen regulator unpause error

0x03 ( 3) Color pen regulator unpause error

0x04 ( 4) CB_5V_TOO_LOW to Carriage PCA. (?? is the A2D value.)

0x05 ( 5) CB_5V_TOO_HIGH to Carriage PCA. (?? is the A2D value.)

0x06 ( 6) CB_12V_TOO_LOW to Carriage PCA. (?? is the A2D value.)

0x07 ( 7) CB_12V_TOO_HIGH to Carriage PCA. (?? is the A2D value.)

0x08 ( 8) CB_32V_TOO_LOW to Carriage PCA. (?? is the A2D value.)

0x09 ( 9) CB_32V_TOO_HIGH to Carriage PCA. (?? is the A2D value.)

0x0A ( 10) CB_VPP1_TOO_LOW (?? Is the reading in volts)

0x0B ( 11) CB_VPP1_TOO_HIGH (?? Is the reading in volts)

0x0C ( 12) CB_VPP2_TOO_LOW (?? Is the reading in volts)

0x0D ( 13) CB_VPP2_TOO_HIGH (?? Is the reading in volts)

0x0E ( 14) Endeavour A2D not ready error.

0x0F ( 15) CB_NO_MICCI_DEVICES (probably no carriage PCA/ broken trailing cable)

0x10 ( 16) CB_SYNERGY_MISSING but Endeavour was found (bad CB)

0x11 ( 17) CB_SYNERGY_ST_ERROR (bad CB)

0x12 ( 18) CB_SYNERGY_A2D_BAD (bad CB)

0x13 ( 19) +12V regulator unpause error (??=regulator status)

0x14 ( 20) Powered off during a pen health test (?)

0x15 ( 21) CB_SYNERGY_MISSING_CLOCK (??: see ERR_ID below)

0x16 ( 22) Synergy was reset (detected after a measurement error).

0x17 ( 23) Shorted Spot sensor (5V to gnd short), causing a synergy error.

0x18 ( 24) CB_SYNERGY_12V_LOST Synergy shut down. (??=1 if retesting)

0x19 ( 25) Black Vpp2 regulator lost (shut down) (??: see ERR_ID below)

0x1A ( 26) Color Vpp1 regulator lost (shut down) (??: see ERR_ID below)

0x1B ( 27) Synergy 12V regulator error (??=regulator status)

0x1C ( 28) Black Vpp2 regulator error (??=regulator status)

0x1D ( 29) Color Vpp1 regulator error (??=regulator status)

0x1E ( 30) Black Vpp calibration error (?? = K Vpp voltage - need > 5V)

0x1F ( 31) Color Vpp calibration error (?? = CMY Vpp voltage - need > 5V)

0x20 ( 32) CB_ENDEAVOUR_MISSING but Synergy was found (bad CB)

0x21 ( 33) CB_ENDEAVOUR_ST_ERROR (bad CB)

0x22 ( 34) CB_ENDEAVOUR_A2D_BAD (bad CB) (?? = a2d reading)

0x23 ( 35) CB_PENS_NOT_POWERED when a routine thought they should be

0x24 ( 36) CB_SPOT_LED_BAD Spot LED is backwards, sensor missing (?? a2d)

0x25 ( 37) CB_DIMPLE_FLEX_BAD_PWR CB hardware error (?? a2d)

0x26 ( 38) CB_DIMPLE_FLEX_BAD_HW CB hardware error (?? a2d)

0x27 ( 39) CB_DIMPLE_FLEX_UNSEATED (check installation) (?? a2d)

0x28 ( 40) CB_DIMPLE_FLEX_MISSING (check installation) (?? a2d)

0x29 ( 41) CBIO asserted after another assert (BOGUS).

0x2A ( 42) CB_VPP_K_CAL_LOW_ERR (?? a2d)

0x2B ( 43) CB_VPP_CMY_CAL_LOW_ERR (?? a2d)

0x2C ( 44) CB_VPP_K_CAL_HIGH_ERR (?? a2d)

0x2D ( 45) CB_VPP_CMY_CAL_HIGH_ERR (?? a2d)

0x2E ( 46) CB_SYNERGY_LOST_12V Synergy shutdown. (not sclk or OT)(??: ERR_ID)

0x2F ( 47) 32V too low when Synergy was found to be reset (??=a2d)

0x30 (48) Black +5V on when it should be off (??: a2d)

0x31 (49) Cyan +5V on when it should be off (??: a2d)

0x32 (50) Magenta +5V on when it should be off (??: a2d)

0x33 (51) Yellow +5V on when it should be off (??: a2d)

0x34 (52) Black +12V on when it should be off (??: a2d)

0x35 (53) Cyan +12V on when it should be off (??: a2d)

0x36 (54) Magenta +12V on when it should be off (??: a2d)

0x37 (55) Yellow +12V on when it should be off (??: a2d)

0x38 (56) CB_NO_ACUMEN_PULLUP (bad CB or a device is grounding the data line)

0x39 (57) CB_NO_ACUMEN_DRIVE (bad CB) (??: a2d)

0x3A (58) Acumen HW8 error (bad Endeavour?) (bad CB)

0x3B (59) Acumen HW9 error (bad Endeavour - won't do multibyte xfer) (bad CB)

0x3C (60) Acumen multibyte read error (bad CB) (mid line test only)

0x3D (61) Acumen Bus fight on all devices (mid line test only)

0x3E (62) Acumen Bus start bit error on all devices (mid line test only)

0x3F (63) Acumen Bus stop bit error on all devices (mid line test only)

0x40 (64) Pen HW Ownership Take error (?? = old/new id)

0x41 (65) Pen HW Ownership Give error (?? = old/new id)

0x42 (66) Endeavour over temperature shutdown event

0x43 (67) Synergy over temperature shutdown event (?? See ERR_ID below)

0x44 (68) 5V too low to Carriage PCA during a retest. (?? is the A2D value.)

0x45 (69) 12V too low to Carriage PCA during a retest. (?? is the A2D value.)

0x46 (70) Vpp2 (black) voltage too high when it should be off - (?? Volts)

0x47 (71) Vpp1 (color) voltage too high when it should be off - (?? Volts)

0x48 (72) Vpp2 (black) failed droop test (?? 0 or resistance/10)

0x49 (73) Vpp1 (color) failed droop test (?? 0 or resistance/10)

0x4A (74) Can't set a pen voltage trim register in Synergy (?? 0:K, 1:CMY)

0x4B (75) Can't turn off Vpp2 (black pen regulator) (?? Trim reg)

0x4C (76) Can't turn off Vpp1 (color pen regulator) (?? Trim reg)

0x4D (77) Can't turn off the 12V regulator (?? Status reg)

0x4E (78) 0x4F (79) 0x50 (80) Obsolete Endeavour ASIC on the carriage PCA.

0x51 (80) Obsolete Synergy ASIC on the carriage PCA.

0x70 () Endeavour Rcal init error (?? = a2d cnts (want ))

0x71 () Endeavour 5V null error (?? = a2d cnts (want ))

0x72 () Endeavour 5V 0mA error (?? = pen id ())

0x73 () Endeavour 5V 10mA error (?? = pen id ())

0x74 () Endeavour 12V null error (?? = a2d cnts (want ))

0x75 () Endeavour 12V 0mA error (?? = pen id ())

0x76 () Endeavour 12V 10mA error (?? = pen id ())

0x77 () Pen Safety Watchdog (?? = last id, current id)

0x78 () Endeavour Rcal now error (?? = a2d cnts (want ))

0x79 () Pause Error{0x7B and 0x7C}(?? = synergy error flags)

0x7A () Verification bad pen trap (?? = pen id)

0x7B () Unpause K unstable data (?? = 1st XOR 2nd)

0x7C () Unpause CMY unstable data (?? = 1st XOR 2nd)

0x7D () Watchdog while in print sweep (??= sec/10) (temporary)

0x7E () Watchdog error while testing (??= reference id) (temporary) ERR_ID: Field used to indicate the calling function for some CBIO errors.
  1. While measuring the black pen voltage

  2. While measuring the color pen voltage

  3. After the 12v Regulator quit

  4. While turning on the 12V regulator

  5. While turning on the black pen regulator

  6. while turning on the color pen regulator

  7. While un-pausing the 12V regulator

  8. While un-pausing the black pen regulator

  9. While un-pausing the color pen regulator

  10. While powering up the carriage pca

  11. While setting a pen voltage

  12. While performing an 'unpause'

  13. Error prior to a cbio watchdog timeout.

  14. While Pausing the black pen regulator

  15. While Pausing the color pen regulator

  16. When 12V was lost during a digital pen test